1. Solid Ground Floor
Scroll over copy
While insulating the floor of an existing building is a disruptive process it shouldn’t be disregarded completely as there are significant benefits in terms of reducing heat loss. Also if part of the remedial work includes plumbing upgrades then it might be prudent to take advantage of this opportunity to provide insulation as the concrete screed will need to be excavated to some extent.
Energy Rating Guidance for Solid Ground Floor (as additional info button)
A B C D E F G
U-Value (W/m2K)
0.12 0.16 0.25 0.70 0.70 0.70 0.70
Insulation
140mm Kooltherm K3 100mm Kooltherm K3 60mm Kooltherm K3 None None None None
Kingspan Kooltherm K3 Floorboard
• Thermal conductivity as low as 0.020
• Can be used in solid and suspended floor construction
• Foil faced on both sides
• Board size: 2.4 x 1.2m
• Board thickness (mm): 30, 40, 50, 60, 70, 80, 90, 100
• Under new building regulations a maximum U-value of 0.15 W/m.K must be achieved in the floor if underfloor heating is used, making Kooltherm K3 the ideal insulant
Download the Refurbishment Solutions Guide for fixing details
2. External rendered insulation system
Scroll over copy
This is an ideal system to upgrade the thermal performance of an existing building as all the work is carried out
externally. Low U-Values are very easily achieved, even exceeding current building regulations for new build!
The roof eaves can be adjusted slightly to take into account the additional depth of insulation and proprietary aluminium cill extentions can be used to dress over the existing concrete cill.
Energy Rating Guidance for External Rendered Insulation System (as additional info button)
A B C D E F G
U-Value (W/m2K)
0.12 0.16 0.27 0.30 0.36 0.43 1.00
Insulation
150mm Kooltherm K5 EWB 110mm Kooltherm K5 EWB 60mm Kooltherm K5 EWB 50mm Kooltherm K5 EWB 40mm Kooltherm K5 EWB 30mm Kooltherm K5 EWB 25mm EPS between battens
Kingspan Kooltherm K5 EWB External Render Board
• Thermal conductivity as low as 0.020
• For use behind traditional and lightweight polymer modified renders
• Tissue faced on both sides
• Board size: 1.2 x 0.6m
• Board thickness: 20, 30, 40, 50, 60, 70, 80, 90, 100
Download the Refurbishment Solutions Guide for fixing details
3. Cold Pitched Roof
Insulating an existing sloped ceiling may be achieved by fitting an insulated plasterboard directly to the underside of the existing plasterboard, but ideally the existing plasterboard should be removed and a new layer of insulation fitted between the rafters, and insulated dry-lining fitted under the rafters.
Energy Rating Guidance for Cold Pitched Roof (as additional info button)
A B C D E F G
U-Value (W/m2K)
0.12 0.14 0.16 0.20 0.30 0.45 0.87
Insulation
Between rafters
Under rafters
150mm Kooltherm K7
72.5mm Kooltherm K17 or K18
150mm Kooltherm K7
52.5mm Kooltherm K17 or K18
100mm Kooltherm K7
62.5mm Kooltherm K17 or K18
100mm Kooltherm K7
42.5mm Kooltherm K17 or K18
100mm Kooltherm K7
60mm Kooltherm K7
100mm Mineral Fibre
Kingspan Kooltherm K7 Pitched Roof Board
• Thermal conductivity as low as 0.020
• For use in flat ceilings and tiled or slated pitched roof spaces
• Ideal for improving the insulation properties of existing buildings
• Foil faced on both sides
• Board size: 2.4 x 1.2m
• Board thickness: 30, 35, 40, 50, 60, 70, 80, 90, 100
Kingspan Kooltherm K17 and K18 Insulated Dry-lining Board
Scroll over copy
• Thermal conductivity as low as 0.020
• For use in internal dry-lining applications
• Optimum building energy ratings can be achieved by combining K17/K18 with Kooltherm K8 Cavity Board
• K17 is plasterboard on one side and tissue faced on the other and should be used for plaster dab/ adhesive bonding
• K18 is plasterboard on one side and foil faced on the other and should be used when mechanical fixing to timber framing/ battens
• Board size: 2.4 x 1.2m
• Board thickness: 25, 30, 40, 50, 60, 70, 80. (all 12.5mm plasterboard)
4. Warm Pitched Roof
This particular system will require removal of the existing slates or tiles and therefore may only be feasible when these need to be replaced as part of the remedial works.
Energy Rating Guidance for Warm Pitched Roof (as additional info button)
A B C D E F G
U-Value (W/m2K)
0.12 0.14 0.16 0.20 0.27 0.45 0.87
Insulation
Between rafters
Over rafters
120mm Kooltherm K7
80mm Kooltherm K7
80mm Kooltherm K7
80mm Kooltherm K7
70mm Kooltherm K7
70mm Kooltherm K7
60mm Kooltherm K7
50mm Kooltherm K7
40mm Kooltherm K7
40mm Kooltherm K7
40mm Kooltherm K7
n/a
Kingspan Kooltherm K7 Pitched Roof Board
• Thermal conductivity as low as 0.020
• For use in flat ceilings and tiled or slated pitched roof spaces
• Ideal for improving the insulation properties of existing buildings
• Foil faced on both sides
• Board size: 2.4 x 1.2m
• Board thickness: 30, 35, 40, 50, 60, 70, 80, 90, 100
5. Flat Ceiling
Insulation already present in a flat ceiling may have deteriorated over the years depending the type, and length of time it has been there. Replacing the existing insulation with Kooltherm K7 between the joists, and the addition of Kooltherm K17 or K18 insulated plasterboard beneath the joists will ensure improved thermal performance of the ceiling for the lifetime of the building.
Energy Rating Guidance for Flat Ceiling (as additional info button)
A B C D E F G
U-Value (W/m2K)
0.12 0.14 0.16 0.20 0.27 0.45 0.87
Insulation
Between rafters
Under rafters
200mm Kooltherm K7
42.5mm Kooltherm K17 or K18
160mm Kooltherm K7
42.5mm Kooltherm K17 or K18
200mm Kooltherm K7
140mm Kooltherm K7
100mm Kooltherm K7
50mm Kooltherm K7
100mm Mineral Fibre
Kingspan Kooltherm K7 Pitched Roof Board
• Thermal conductivity as low as 0.020
• For use in flat ceilings and tiled or slated pitched roof spaces
• Ideal for improving the insulation properties of existing buildings
• Foil faced on both sides
• Board size: 2.4 x 1.2m
• Board thickness: 30, 35, 40, 50, 60, 70, 80, 90, 100
Kingspan Kooltherm K17 and K18 Insulated Dry-lining Board
Scroll over copy
• Thermal conductivity as low as 0.020
• For use in internal dry-lining applications
• Optimum building energy ratings can be achieved by combining K17/K18 with Kooltherm K8 Cavity Board
• K17 is plasterboard on one side and tissue faced on the other and should be used for plaster dab/ adhesive bonding
• K18 is plasterboard on one side and foil faced on the other and should be used when mechanical fixing to timber framing/ battens
• Board size: 2.4 x 1.2m
• Board thickness: 25, 30, 40, 50, 60, 70, 80. (all 12.5mm plasterboard)
6. Internal Dry-lining
Traditionally internal dry-lining has been the preferred method of improving the thermal performance of existing walls. Using premium performance Kingspan Kooltherm K17 or K18 products will ensure the thinnest and most effective solution and will considerably reduce heat loss.
It is also ideal to accompany K7 in Cold Pitched Roof and Flat Ceiling upgrades.
Energy Rating Guidance for Internal Dry-lining walls (as additional info button)
A B C D E F G
U-Value (W/m2K)
0.12 0.16 0.27 0.30 0.34 0.43 1.00
Insulation
Between studwork
Fixed to inside of studs
100mm Kooltherm K12
92.5mm Kooltherm K18
70mm Kooltherm K12
82.5mm Kooltherm K18
82.5mm Kooltherm K17 or 72.5mm Kooltherm K18
72.5mm Kooltherm K17 or 62.5mm Kooltherm K18
62.5mm Kooltherm K17 or 52.5mm Kooltherm K18
52.5mm Kooltherm K17 or 42.5mm Kooltherm K18
25mm EPS between battens
Kingspan Kooltherm K17 and K18 Insulated Dry-lining Board
Scroll over copy
• Thermal conductivity as low as 0.020
• For use in internal dry-lining applications
• Optimum building energy ratings can be achieved by combining K17/K18 with Kooltherm K8 Cavity Board
• K17 is plasterboard on one side and tissue faced on the other and should be used for plaster dab/ adhesive bonding
• K18 is plasterboard on one side and foil faced on the other and should be used when mechanical fixing to timber framing/ battens
• Board size: 2.4 x 1.2m
• Board thickness: 25, 30, 40, 50, 60, 70, 80. (all 12.5mm plasterboard)
Kingspan Kooltherm K12 Framing Board
Scroll over copy
• Thermal conductivity as low as 0.020
• Can be used between studs or as an insulated sheathing
• Suitable for use with timber frame and steel wall constructions
• Foil faced on both sides
• Board size: 2.4 x 1.2m
• Board thickness: 30, 40, 50, 60, 70, 80, 90, 100